Human DNA replication licensing factor MCM2 ELISA Kit is an ELISA kit against Human DNA replication licensing factor MCM2 (MCM2).

Target DNA replication licensing factor MCM2
Reactivity Human
Tested Applications ELISA
Recommended dilutions Optimal dilutions/concentrations should be determined by the end user.
Storage Shipped at 4 °C. Upon receipt, store the kit according to the storage instruction in the kit's manual.
Validity The validity for this kit is 6 months.
Stability The stability of the kit is determined by the rate of activity loss. The loss rate is less than 5% within the expiration date under appropriate storage conditions. To minimize performance fluctuations, operation procedures and lab conditions should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same user throughout.
UniProt Primary AC P49736 (UniProt, ExPASy)
UniProt Secondary AC Q14577, Q15023, Q8N2V1, Q969W7, Q96AE1, Q9BRM7
UniProt Entry Name MCM2_HUMAN
Gene Symbol MCM2
KEGG hsa:417
String 9606.ENSP00000265056
Test Range 78 pg/ml - 5000 pg/ml
Standard Form Lyophilized
ELISA Detection Colorimetric
ELISA Type Sandwich
ELISA Data Quantitative
Sample Type Serum, plasma and other biological fluids.
Assay Principle This kit is based on sandwich enzyme-linked immuno-sorbent assay technology. An antibody is pre-coated onto a 96-well plate. Standards, test samples, and biotin-conjugated reagent are added to the wells and incubated. The HRP-conjugated reagent is then added, and the whole plate is incubated. Unbound conjugates are removed using wash buffer at each stage. TMB substrate is used to quantify the HRP enzymatic reaction. After TMB substrate is added, only wells that contain sufficient MCM2 will produce a blue coloured product, which then changes to yellow after adding the acidic stop solution. The intensity of the yellow colour is proportional to the MCM2 amount bound on the plate. The Optical Density (OD) is measured spectrophotometrically at 450 nm in a microplate reader, from which the concentration of MCM2 can be calculated.
Kit Components
  • Pre-coated 96-Well Microplate
  • Standard
  • Standard Diluent Buffer
  • Wash Buffer
  • Detection Reagent A
  • Detection Reagent B
  • Diluent A
  • Diluent B
  • TMB Substrate
  • Stop Solution
  • Plate Sealer
Material Required But Not Provided
  • 37°C incubator
  • Multi and single channel pipettes and sterile pipette tips
  • Squirt bottle or automated microplate washer
  • 1.5 ml tubes
  • Distilled water
  • Absorbent filter papers
  • 100 ml and 1 liter graduated cylinders
  • Microplate reader (wavelength: 450 nm)
  • ELISA Shaker
Sample Collection/Preparation
  • Serum: Samples should be collected into a serum separator tube. Coagulate the serum by leaving the tube undisturbed in a vertical position overnight at 4°C or at room temperature for up to 60 minutes. Centrifuge at approximately 1000 × g for 20 min. Analyze the serum immediately or aliquot and store at -20°C or -80°C.
  • Plasma: Collect plasma using heparin or EDTA as an anticoagulant. Centrifuge for 15 minutes at 1000 × g within 30 minutes of collection. Assay immediately or aliquot and store at -20°C or -80°C. Avoid hemolysis and high cholesterol samples.
  • Tissue homogenates: The preparation of tissue homogenates will vary depending upon tissue type – this is just an example. Rinse tissues with ice-cold PBS to remove the excess of blood. Weigh before homogenization. Finely mince tissues and homogenize with a tissue homogenizer on ice in PBS and sonicate the cell suspension. Centrifuge the homogenates at 5000 × g for 5 min and collect the supernatant. Assay immediately or aliquot and store at -20°C.
Reagent Preparation
  • 1) Standard: Prepare the standard with the recommended volume of Standard Diluent Buffer, to make the standard solution. Then use the Standard Diluent buffer to carry out serial dilutions of the standard solution, as instructed in the Protocol.
  • 2) Wash Buffer: Dilute the concentrated Wash Buffer with distilled water, as instructed in the Protocol.
  • 3) Detection Reagent Preparation: Calculate the total volume of working solution required. Dilute Detection Reagent A and Detection Reagent B with Diluent A and Diluent B, respectively, at 1:100.
Assay Procedure
  • 1) Set standard, test samples and control wells.
  • 2) Aliquot 100 μl of diluted standard into the standard wells.
  • 3) Aliquot 100 μl of Standard Diluent buffer into control (zero) well.
  • 4) Aliquot 100 μl of diluted samples into the sample wells. Incubate for 1 hr at 37 °C.
  • 5) Aliquot 100 μl of Detection Reagent A to each well. Incubate for 1 hr at 37 °C.
  • 6) Wash 3 times.
  • 7) Aliquot 100 μl of Detection Reagent B to each well. Incubate for 30 mins at 37 °C.
  • 8) Wash 5 times.
  • 9) Aliquot 90 μl of TMB Substrate to each well. Incubate for 10-20 mins at 37 °C.
  • 10) Aliquot 50 μl of Stop Solution.
  • 11) Measure the OD at 450 nm.
Protocol
  • Equilibrate the kit components and samples to room temperature (18 - 25 °C) before use. It is recommended to plot a standard curve for each test.
  • 1. Set standard, test sample and control (zero) wells on the pre-coated plate respectively, and then, record their positions. It is recommended to measure each standard and sample at least in duplicate.
  • 2. Add 100 µL of each standard, control and sample into the appropriate wells. Seal the plate with a cover and incubate for 1 h at 37°C.
  • 3. Remove the cover and discard the liquid.
  • 4. Add 100 μl of the detection Reagent A working solution to each well. Seal the plate with a cover and incubate for 1 h at 37°C.
  • 5. Remove the cover and discard the solution. Wash the plate 3 times with 1X Wash Buffer.
  • 6. Add 100 µL of Detection Reagent B working solution into each well, seal and incubate at 37°C for 30 min.
  • 7. Discard the solution and wash the plate 5 times with wash buffer as explained in previous step.
  • 8. Aliquot 90 μl of TMB Substrate into each well. Seal the plate with a cover and incubate at 37°C for 10-20 min. Avoid exposure to light. The incubation time is for reference use only, the optimal time should be determined by end user. Do not exceed 30 min.
  • 9. Add 50 µL of Stop Solution to each well. Read at 450 nm immediately.
Results Calculation For calculation, average the O.D.450 duplicate readings for each reference standard and each sample and substract the average control (zero) O.D.450 reading. The standard curve can be plotted as the relative O.D.450 of each reference standard solution (Y) vs. the respective concentration of each standard solution (X). The MCM2 concentration of the samples can be interpolated from the standard curve.
Availability Shipped within 5-12 working days.
Note This product is for research use only.

The range and sensitivity is subject to change. Please contact us for the latest product information. For accurate results, sample concentrations must be diluted to mid-range of the kit. If you require a specific range, please contact us in advance or write your request in your order comments.

Please note that our ELISA and CLIA kits are optimised for detection of native samples, rather than recombinant proteins. We are unable to guarantee detection of recombinant proteins, as they may have different sequences or tertiary structures to the native protein.
Research Articles on Human Minichromosome Maintenance Complex Component 2 (MCM2) ELISA Kit

Write a review

Your Name
Your Email Address
PMID
DOI
Type
Your Review

Note: HTML is not translated!

Rating Bad Good


Tags:
(Click to show)