Mouse Coagulation Factor VIII (F8) ELISA Kit

REQUEST MORE INFO
Catalogue No: abx254094
Price: US$652.50
(Size: 96 tests)

Click on the image to see the image legend

Available Options

* Size:

Add to Shopping Cart Buy It Now GET A QUOTE
Mouse Coagulation Factor VIII (F8) ELISA Kit is an ELISA Kit for the in vitro quantitative measurement of Mouse Coagulation Factor VIII concentrations in plasma.

Introduction Factor VIII (FVIII) is a blood protein that promotes coagulation. It is typically bound to von Willebrand factor (vWF) to keep it inactive, but later separates from this protein in response to vascular damage. Active FVIII (FVIIIa) works as a cofactor to help factor IXa to cleave factor X, allowing the coagulation cascade to progress. FVIIIa is deactivated by factor IXa, protein C, and other proteases. Low levels of factor VIII result from the X-linked genetic disorder Haemophilia A, which leads to an increased bleeding time before coagulation and increases the risks from trauma. HIV-contaminated factor VIII products were responsible for a number of pharmaceutical scandals in the 1980s.
Target Coagulation Factor VIII (F8)
Reactivity Mouse
Tested Applications ELISA
Recommended dilutions Optimal dilutions/concentrations should be determined by the end user.
Storage Shipped at 4 °C. Upon receipt, store the kit according to the storage instruction in the kit's manual.
Validity The validity for this kit is at least 6 months. Up to 12 months validity can be provided on request.
Stability The stability of the kit is determined by the rate of activity loss. The loss rate is less than 5% within the expiration date under appropriate storage conditions. To minimize performance fluctuations, operation procedures and lab conditions should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same user throughout.
Test Range 0.156 ng/ml - 10 ng/ml
Sensitivity 0.1 ng/ml
Standard Form Lyophilized
Detection Method Colorimetric
Assay Type Sandwich
Assay Data Quantitative
Sample Type Plasma.
Kit Components The kit components listed are for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.
  • Pre-coated 96-Well Microplate
  • Standard
  • Standard Diluent Buffer
  • Wash Buffer
  • Detection Reagent A
  • Detection Reagent B
  • Diluent A
  • Diluent B
  • TMB Substrate
  • Stop Solution
  • Plate Sealer
Material Required But Not Provided
  • 37°C incubator
  • Multi and single channel pipettes and sterile pipette tips
  • Squirt bottle or automated microplate washer
  • 1.5 ml tubes
  • Distilled water
  • Absorbent filter papers
  • 100 ml and 1 liter graduated cylinders
  • Microplate reader (wavelength: 450 nm)
  • ELISA Shaker
Assay Procedure This procedure is provided for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.
  • 1) Set standard, test samples and control wells.
  • 2) Aliquot 100 µl of diluted standard into the standard wells.
  • 3) Aliquot 100 µl of Standard Diluent buffer into control (zero) well.
  • 4) Aliquot 100 µl of diluted samples into the sample wells. Incubate for 1 hr at 37 °C.
  • 5) Aliquot 100 µl of Detection Reagent A to each well. Incubate for 1 hr at 37 °C.
  • 6) Wash 3 times.
  • 7) Aliquot 100 µl of Detection Reagent B to each well. Incubate for 90 mins at 37 °C.
  • 8) Wash 5 times.
  • 9) Aliquot 90 µl of TMB Substrate to each well. Incubate for 10-20 mins at 37 °C.
  • 10) Aliquot 50 µl of Stop Solution.
  • 11) Measure the OD at 450 nm.
Assay Precision Intra-assay Precision (Precision within an assay): 3 samples with low, medium and high levels of Coagulation Factor VIII were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, medium and high levels of Coagulation Factor VIII were tested on 3 different plates, 8 replicates in each plate.

CV (%) = (Standard Deviation / mean) × 100

Intra-Assay: CV<10%

Inter-Assay: CV<10%
Availability Shipped within 5-7 working days.
Note This product is for research use only.

The range and sensitivity is subject to change. Please contact us for the latest product information. For accurate results, sample concentrations must be diluted to mid-range of the kit. If you require a specific range, please contact us in advance or write your request in your order comments.

Please note that our ELISA and CLIA kits are optimised for detection of native samples, rather than recombinant proteins. We are unable to guarantee detection of recombinant proteins, as they may have different sequences or tertiary structures to the native protein.
Plate coated with Antibody
Research Articles on Coagulation Factor VIII (F8)


Write a review

Tags:
(Click to show)