Electrofusion Buffer

REQUEST MORE INFO
Catalogue No: abx094001
Price: US$536.50
(Size: 500 ml)

Orders to United States ship from United States

Click on the image to see the image legend

Available Options

* Size:

Add to Cart Buy It Now GET A QUOTE
Electrofusion Buffer is a a specialized, low-conductivity solution used for electrofusion of hybridomas, increasing positive clone yield and fusion efficiency. It can be used for monoclonal antibody preparation, cell fusion experiments and cell engineering research.

This product is suitable for use with most brands of electroporation instruments.

Target Electrofusion Buffer
Research Area Cell Culture, Cell Fusion, Hybridoma Technology, Cell Engineering
Form Liquid
Purity Conductivity: 0.080 ± 0.005 mS/cm at 25°C.
Osmolality: 130-180 mOsm/l.
Purification 0.22 µm sterile filtered.
Storage Store at 2-8°C.
Shelf Life 18 months.
Buffer pH 7.2 ± 0.2.
Endotoxin Level < 0.25 EU/ml
Concentration 1X
Availability Shipped within 5-7 working days.
Note THIS PRODUCT IS FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC, THERAPEUTIC OR COSMETIC PROCEDURES. NOT FOR HUMAN OR ANIMAL CONSUMPTION.
Directions for use Recommended Cell Electrofusion Protocol

Cell Preparation:

  1. Collect spleen cells from euthanized mice.
  2. Resuspend the cell in 15 ml 10% red blood cell lysis buffer and centrifuge at 1200 rpm for 5 minutes.
  3. Wash the cells twice with basal DMEM, centrifuge at 1200 rpm for 5 minutes.
  4. Resuspend in 10 ml DMEM and count (Usually 1 × 108- 2.5 × 108 from a Mouse spleen and 5 × 108- 10 × 108 from a Rat spleen.)

Myeloma Cell Preparation:

  1. Collect SP2/0 Mouse myeloma cells.
  2. Resuspend 10 ml DMEM and count.

Fusion Chamber Preparation:

  1. Place the fusion/electrode chamber on ice (0-4°C) for at least 30 minutes before use.
  2. Take out the fusion chamber and add an equal volume (usually 2 ml or 9 ml) 75% ethanol. Incubate for 10 minutes.
  3. Rinse twice with ddH2O, and then rinse twice with Electrofusion Buffer.

Electrofusion Procedure:

  1. Collect the total number of cells required for experimental requirements. It is recommended that the ratio of spleen cells to myeloma cells is 1:1 for cell fusion.
  2. Wash 2-3 times with Electrofusion Buffer and centrifuge at 1200 rpm for 5 minutes.
  3. Resuspend in Electrofusion Buffer- the final recommended concentration is 1 × 107 cells/ml.
  4. Briefly mix the suspension and transfer to the prepared 2 ml or 9 ml fusion chamber.
Note: Ensure the fusion procedure begins within 30 seconds of the cells entering the fusion chamber, and within 10 minutes of washing the cells with the Fusion Buffer. If the cells sink to the bottom of the chamber, use a pipette to gently resuspend.

Post-fusion handling and plating:
  1. After completing the procedure, let it stand for 2-3 minutes and collect the cells in the prepared fusion medium. Place in a CO2 incubator at 37°C for 1 hour.
  2. Determine the number of 96 well culture plates and distribute as required.
Notes:
  • Use standard sterile culture techniques to avoid contamination.
  • This product is non-toxic, but does not contain nutrients to support cell survival. It is recommended to complete the electrofusion within 1 hour after washing with the buffer, and to minimise the duration that the cells are suspended in this product.
  • For maxiumum fusion efficiency, it is recommended to use this product at room temperature.

Research Articles on Electrofusion Buffer


Write a review