Human Chymase 1, Mast Cell (CMA1) ELISA Kit

REQUEST MORE INFO
Catalogue No: abx251407
Price: US$652.50
(Size: 96 tests)

Click on the image to see the image legend

Available Options

* Size:

Add to Shopping Cart Buy It Now GET A QUOTE
Human Chymase 1, Mast Cell (CMA1) ELISA Kit is an ELISA Kit for the in vitro quantitative measurement of Human Chymase 1, Mast Cell (CMA1) concentrations in serum, plasma, tissue homogenates, cell lysates and other biological fluids.

Introduction Chymase is an enzyme that in humans is encoded by the CMA1 gene. his gene product is a chymotryptic serine proteinase that belongs to the peptidase family S1. It is expressed in mast cells and thought to function in the degradation of the extracellular matrix, the regulation of submucosal gland secretion, and the generation of vasoactive peptides. In the heart and blood vessels, this protein, rather than angiotensin converting enzyme, is largely responsible for converting angiotensin I to the vasoactive peptide angiotensin II. Angiotensin II has been implicated in blood pressure control and in the pathogenesis of hypertension, cardiac hypertrophy, and heart failure. Thus, this gene product is a target for cardiovascular disease therapies. This gene maps to 14q11.2 in a cluster of genes encoding other proteases.
Target Chymase 1, Mast Cell (CMA1)
Reactivity Human
Tested Applications ELISA
Recommended dilutions Optimal dilutions/concentrations should be determined by the end user.
Storage Shipped at 4 °C. Upon receipt, store the kit according to the storage instruction in the kit's manual.
Validity The validity for this kit is at least 6 months. Up to 12 months validity can be provided on request.
Stability The stability of the kit is determined by the rate of activity loss. The loss rate is less than 5% within the expiration date under appropriate storage conditions. To minimize performance fluctuations, operation procedures and lab conditions should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same user throughout.
UniProt Primary AC P23946 (UniProt, ExPASy)
UniProt Entry Name CMA1_HUMAN
Gene Symbol CMA1
GeneID 1215
OMIM 118938
HGNC 2097
KEGG hsa:1215
String 9606.ENSP00000250378
Test Range 78 pg/ml - 5000 pg/ml
Sensitivity 46.9 pg/ml
Standard Form Lyophilized
Detection Method Colorimetric
Assay Type Sandwich
Assay Data Quantitative
Sample Type Serum, plasma, tissue homogenates, cell lysates and other biological fluids.
Kit Components The kit components listed are for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.
  • Pre-coated 96-Well Microplate
  • Standard
  • Standard Diluent Buffer
  • Wash Buffer
  • Detection Reagent A
  • Detection Reagent B
  • Diluent A
  • Diluent B
  • TMB Substrate
  • Stop Solution
  • Plate Sealer
Material Required But Not Provided
  • 37°C incubator
  • Multi and single channel pipettes and sterile pipette tips
  • Squirt bottle or automated microplate washer
  • 1.5 ml tubes
  • Distilled water
  • Absorbent filter papers
  • 100 ml and 1 liter graduated cylinders
  • Microplate reader (wavelength: 450 nm)
  • ELISA Shaker
Assay Procedure This procedure is provided for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.
  • 1) Set standard, test samples and control wells.
  • 2) Aliquot 100 µl of diluted standard into the standard wells.
  • 3) Aliquot 100 µl of Standard Diluent buffer into control (zero) well.
  • 4) Aliquot 100 µl of diluted samples into the sample wells. Incubate for 1 hr at 37 °C.
  • 5) Aliquot 100 µl of Detection Reagent A to each well. Incubate for 1 hr at 37 °C.
  • 6) Wash 3 times.
  • 7) Aliquot 100 µl of Detection Reagent B to each well. Incubate for 90 mins at 37 °C.
  • 8) Wash 5 times.
  • 9) Aliquot 90 µl of TMB Substrate to each well. Incubate for 10-20 mins at 37 °C.
  • 10) Aliquot 50 µl of Stop Solution.
  • 11) Measure the OD at 450 nm.
Assay Precision Intra-assay Precision (Precision within an assay): 3 samples with low, medium and high levels of Chymase 1, Mast Cell (CMA1) were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, medium and high levels of Chymase 1, Mast Cell (CMA1) were tested on 3 different plates, 8 replicates in each plate.

CV (%) = (Standard Deviation / mean) × 100

Intra-Assay: CV<10%

Inter-Assay: CV<10%
Availability Shipped within 5-7 working days.
Note This product is for research use only.

The range and sensitivity is subject to change. Please contact us for the latest product information. For accurate results, sample concentrations must be diluted to mid-range of the kit. If you require a specific range, please contact us in advance or write your request in your order comments.

Please note that our ELISA and CLIA kits are optimised for detection of native samples, rather than recombinant proteins. We are unable to guarantee detection of recombinant proteins, as they may have different sequences or tertiary structures to the native protein.
Plate coated with Antibody
Research Articles on Chymase 1, Mast Cell (CMA1)


Write a review

Tags:
(Click to show)