Folic Acid / Vitamin B9 ELISA Kit
REQUEST MORE INFO
Catalogue No: abx150387
Price:
US$862.75
(Size: 96 tests)
Orders to United States ship from United States
Add to Cart
Buy It Now
GET A QUOTE
Documents
Download IFU SDS
Folic Acid / Vitamin B9 (FA) ELISA Kit is an ELISA Kit for the in vitro quantitative measurement of Folic Acid / Vitamin B9 (FA) concentrations in serum, plasma, tissue homogenates, cell lysates, cell culture supernatants and other biological fluids. This assay has high sensitivity and excellent specificity for detection of Vitamin B9 (VB9)
No significant cross-reactivity or interference between Vitamin B9 (VB9) and analogues was observed.
Research Articles on Folic Acid / Vitamin B9
No significant cross-reactivity or interference between Vitamin B9 (VB9) and analogues was observed.
| Introduction | Folate, distinct forms of which are known as folic acid, folacin, and vitamin B9, is one of the B vitamins. Folic acid is essential for the body to make DNA, RNA, and metabolise amino acids, which are required for cell division. Not consuming enough folate can lead to folate deficiency. This may result in a type of anemia in which low numbers of large red blood cells occur. |
| Target | Folic Acid / Vitamin B9 |
| Research Area | Hematology, Reproductive Science, Nutrition |
| Reactivity | General (All species) |
| Tested Applications | ELISA |
| Recommended dilutions | Optimal dilutions/concentrations should be determined by the end user. |
| Storage | Shipped at 4°C. Upon receipt, store the kit according to the storage instruction in the kit's manual. |
| Shelf Life | Up to 12 months. |
| Stability | The stability of the kit is determined by the rate of activity loss. The loss rate is less than 5% within the expiration date under appropriate storage conditions. To minimize performance fluctuations, operation procedures and lab conditions should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same user throughout. |
| Test Range | 0.78 ng/ml - 200 ng/ml |
| Sensitivity | < 0.29 ng/ml |
| Standard Form | Lyophilized |
| Detection Method | Colorimetric |
| Assay Type | Competitive |
| Assay Data | Quantitative |
| Sample Type | Serum, plasma, tissue homogenates, cell lysates, cell culture supernatants and other biological fluids. |
| Target Type | Antigen |
| Assay Principle | This kit is based on competitive enzyme-linked immuno-sorbent assay technology. An antibody is pre-coated onto a 96-well plate. Standards, test samples, and biotin-conjugated reagent are added to the wells and incubated. A competitive inhibition reaction takes place between the biotin-labelled FA and the unlabelled- FA on the pre-coated antibody. The HRP-conjugated reagent is then added, and the whole plate is incubated. Unbound conjugates are removed using wash buffer at each stage. TMB substrate is used to quantify the HRP enzymatic reaction. After TMB substrate is added, only wells that contain sufficient FA will produce a blue coloured product, which then changes to yellow after adding the acidic stop solution. The intensity of the color yellow is inversely proportional to the FA amount bound on the plate. The OD is measured spectrophotometrically at 450 nm in a microplate reader, from which the concentration of FA can be calculated. |
| Kit Components | The kit components listed are for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.
|
| Material Required But Not Provided |
|
| Reagent Preparation | This procedure is provided for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.
|
| Assay Procedure | This procedure is provided for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.
|
| Protocol | This procedure is provided for reference only. The product manual may differ slightly. The product should be used as stated on the product manual included and delivered together with the product.
|
| Results Calculation | This assay is competitive, therefore there is an inverse correlation between FA concentration in the sample and the absorbance measured. Create a graph with the log of the standard concentration (y-axis) and average absorbance measured (x-axis). Apply a best fit trendline through the standard points. The FA concentration of the samples can be interpolated from the standard curve. |
| Assay Precision | Intra-assay Precision (Precision within an assay): 3 samples with low, medium and high levels of Folic Acid / Vitamin B9 (FA) were were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, medium and high levels of Folic Acid / Vitamin B9 (FA) were tested on 3 different plates, 8 replicates in each plate. CV (%) = (Standard Deviation / mean) × 100 Intra-Assay: CV<10% Inter-Assay: CV<12% |
| Availability | Shipped within 5-7 working days. |
| Note | THIS PRODUCT IS FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES. The range and sensitivity is subject to change. Please contact us for the latest product information. For accurate results, sample concentrations must be diluted to mid-range of the kit. If you require a specific range, please contact us in advance or write your request in your order comments. Please note that our kits are optimised for detection of native samples, rather than recombinant proteins. We are unable to guarantee detection of recombinant proteins, as they may have different sequences or tertiary structures to the native protein. |
| Standard | 10000 ng/ml |